1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
|
#!/usr/bin/env python3
import logging
import os
import signal
import sqlite3
import sys
import time
import yaml
from RFXtrx import PySerialTransport
def setup_database(database_path, logger):
db_connection = sqlite3.connect(database_path)
db_cursor = db_connection.cursor()
try:
db_cursor.execute("CREATE TABLE weather( \
id INTEGER PRIMARY KEY, \
timestamp DATETIME, \
handle TEXT, \
temperature FLOAT, \
humidity FLOAT);")
except sqlite3.OperationalError:
logger.info("Not re-creating 'weather' table")
pass
return db_connection
def setup_serial(device_path):
serial_connection = PySerialTransport(device_path)
serial_connection.reset()
return serial_connection
def add_data_to_db(data, handle, db_connection):
db_cursor = db_connection.cursor()
db_cursor.execute(f"INSERT INTO weather \
(timestamp, handle, temperature, humidity) \
VALUES ( {int(time.time())}, \
\"{handle}\", \
{data.values['Temperature']}, \
{data.values['Humidity']})")
db_connection.commit()
def loop(config, serial_connection, db_connection, logger):
known_devices = config["known_devices"][config["active_location"]]
while True:
logger.info("(Re-)Starting receiver loop")
data = serial_connection.receive_blocking()
if data is None:
logger.info("Didn't receive data")
continue
logger.info(data)
try:
if data.device.id_string not in known_devices:
logger.info(f"Unknown device with id '{device_id}' and type '{device_type}', ignoring")
continue
except:
logger.info("Device ID not found, likely not a 'SensorEvent', ignoring")
continue
handle = known_devices[data.device.id_string]["handle"]
add_data_to_db(data, handle, db_connection)
def write_pid_file(pid_file_path, logger):
if os.path.exists(pid_file_path):
with open(pid_file_path, "r") as pid_file:
pid = pid_file.read()
logger.error(f"Possibly already running with PID {pid}, exiting")
sys.exit(1)
with open(path, "w") as pid_file:
pid_file.write(str(os.getpid()))
def load_config(config_file_path, logger):
with open(config_file_path, "r") as f:
config = yaml.safe_load(f.read())
logger.info(f"Loaded configuration from '{config_file_path}'")
return config
if __name__ == "__main__":
# logger setup
logging.basicConfig(format='%(asctime)-2s %(levelname)-8s %(message)s',
datefmt='%Y-%m-%dT%H:%M:%S',
level=logging.INFO)
logger = logging.getLogger("weather-logger-receiver")
# load configuration
if len(sys.argv) != 2:
logger.error("Missing path to configuration file, exiting")
sys.exit(1)
config_file_path = sys.argv[1]
config = load_config(config_file_path, logger)
# get known devices
active_location = config["active_location"]
known_devices = config["locations"][active_location]
logger.info(f"Loaded known devices for location '{active_location}'")
# write pid file
write_pid_file(config["pid_file_path"], logger)
logger.info("Wrote PID file to '{config{'pid_file_path']}'")
# database setup
db_connection = setup_database(config["database_path"], logger)
logger.info("Set up database '{config['database_path']}'")
# serial connection setup
serial_connection = setup_serial(config["device_path"])
logger.info("Set up serial connection to '{config['device_path']}'")
# handle shutdown
def shutdown(*args):
logger.info("Shutting down")
serial_connection.close()
db_connection.close()
try:
os.remove(config["pid_file_path"])
except FileNotFoundError:
pass
sys.exit(0)
signal.signal(signal.SIGINT, shutdown)
signal.signal(signal.SIGTERM, shutdown)
# start main loop
try:
loop(known_devices, serial_connection, db_connection, logger)
except Exception as e:
logger.error(f"Exception: '{e}'")
finally:
shutdown(config, serial_connection, db_connection, logger)
|